| Low Sensitivity Range: | Optional Low Range Sensitivity: | Top Of Range: | Power: | Model Numbers: | Standard Options Comments: |
|---|---|---|---|---|---|
| Modular Configuration: | |||||
| 10-8µCi/m3 |   | 4 plus decades 1 to 19,999µCi/m3 |
110/230AC 50/60Hz |
Main Unit 300 Series Monitors |
Single Range |
| 10-8µCi/m3 | 9 plus decades 0.001mCi/m3-1,000Ci/m3 |
110/230AC 50/60Hz |
400 Series Monitors | Auto Ranging 5 ranges standard 7 ranges optional |
|
| 1µCi/m3 | 0.1µCi/m3 | 1-1,999Ci/m3 1-1,999Ci/m3 1-99,999mCi/m3 1-99,999µCi/m3 0.1-1,999.9µCi/m3 |
110/230AC 50/60Hz |
Ionization Chamber 311 Series Monitors |
Single 2 Liter Chamber, optional sizes available; 10cc, 50cc, 200cc, 1L, 8L |
| 1µCi/m3 | 0.01µCi/m3 | 1-1,999Ci/m3 1-1,999Ci/m3 1-99,999mCi/m3 1-99,999µCi/m3 0.1-1,999.9µCi/m3 |
110/230AC 50/60Hz |
411 Series Monitors | Single 2 Liter Chamber, optional sizes available; 10cc, 50cc, 200cc, 1L, 8L |
| 10-8µCi/m3 | 4 plus decades 1 to 19,999µSv/hr |
110/230AC 50/60Hz |
321 Series Monitors | Dual (gamma compensated) 2 Liter Chamber, optional sizes available Dual 8L (wire grid design) for best gamma compensation |
|
| 10-8µCi/m3 | 9 plus decades 0.001Ci/m3 to 1,000 Ci/m3 0.0001Ci/m3-100 Ci/m3 0.001Ci/m3-1,000 Ci/m3 |
110/230AC 50/60Hz |
421 Series Monitors | Dual (gamma compensated) 2 Liter Chamber, optional sizes available Dual 8L (wire grid design) for best gamma compensation |
|
| Fixed Configuration: | |||||
| 10-8µCi/m3 | 4 plus decades 1-19.999mCi/m3 |
110/230AC 50/60Hz |
321 NPPM Series Monitors | Std: Dual Flow 2 Liter Chamber (wire grid design) and a recycling dryer system for differential measurement Options: Noble Gas Comp RS232 Serial Output 4-20mA Output |
|
| 10-8µCi/m3 | 7 plus decades 0.001mSv/hr-20 Sv/hr |
110/230AC 50/60Hz |
421 NPPM Series Monitors | Std: Dual Flow 2 Liter Chamber (wire grid design) and a recycling dryer system for differential measurement Options: Noble Gas Comp RS232 Serial Output 4-20mA Output |
|
| Low Cost Tritium Monitors | |||||
| 10-8µCi/m3 | 0.01 to 199.9MBq/m3 | 4 plus decades 0.01 to 199.9MBq/m3 |
110/230AC 50/60Hz |
357 Monitors | Std: Dual Flow 2 Liter Chambers for Gamma Compensation Options: Wire Grid Chamber(s) RS232 Serial Output Logarithmic Signal Output 4-20mA Output |
| 10-8µCi/m3 | 0.01 to 199.9MBq/m3 | 4 plus decades 0.01 to 199.9MBq/m3 |
110/230AC 50/60Hz |
347 Monitors | Std: Dual Flow 2 Liter Chambers for Gamma Compensation Options: Wire Grid Chamber(s) RS232 Serial Output Logarithmic Signal Output 4-20mA Output |
| Ultra Low Level Monitors | |||||
| 1 X 10-9µCi/m3 | 0 to 10Ci/m3 | 115/230AC 50/60Hz |
93-WR-T-HTO Series | ||
| 3 X 10-9µCi/m3 | 0 to 2MBq/m3 0 to 50µCi/m3 |
115/230AC 50/60Hz |
93-WR-T-HTO Series | ||
| Portable Tritium Monitors | |||||
| 0.2µCi/m3 | Single Range 0.01 to 199.9MBq/m3 Dual Range 0.01 to 199.9MBq/m3 |
19,999mCi/m3 | Batteries | SP1400 Series | |
| 0.2µCi/m3 | 0 to 199.99MBq/m3 0.1 to 1999.9 MPCa |
19.999µCi/m3 | Batteries 2 ea: D-Cell 100--240VAC input-converts to 3.3VDC-output |
400SBDgC Series | |
| Testing & Calibration Equipment: | |||||
| 10-8µCi/m3 | 199.99µCi/m3 | Batteries 2 ea D-Cell |
EC200 Series | ||
| 10-8µCi/m3 | 199.990µCi/m3 | Batteries 2 ea D-Cell |
200BC Series | ||
| 10-8µCi/m3 | Three Ranges: 40 to 400 MBq/m3 4 to 40 MBq/m3 0.4 to 4 MBq/m3 |
Three Ranges: 10KµCi/m3 1KµCi/m3 100µCi/m3 |
Batteries 6 ea D-Cell |
394 Series | |
| 10-8µCi/m3 | No options available | 10KµCi/m3 1KµCi/m3 100µCi/m3 |
Batteries 6 ea D-Cell |
AN/PDR-74 Military Version of Model 394 |
  |
| Surface Contamination Monitors | Optional Low Range Sensitivity: | Top Of Range: | Power: | Model Numbers: | Comments: |
|---|---|---|---|---|---|
| Speedy Ferret STB-TF-6 | Speedy Ferret STB-TF-6.pdf | ||||
| Flat Ferret PTS-26 and 27 | Flat Ferret PTS-26 and 27 | ||||
| SCM-1 (Flat Ferret) | |||||
| SCM-3 (Floor Ferret) | |||||
| SCM-4 (Speedy Ferret) | |||||
| Passive Samplers: | |||||
| 10-9µCi/m3 | 110/230AC 50/60Hz |
TASC Series | |||
| Environmental Gamma Monitors | |||||
| 0.1µR/hr | 200 mR/h | 110/230AC 50/60Hz |
HPIC Series | ||
| Nobel Gas Beta/Gamma Monitors-Scintillation Detectors |
|||||
| ± x 104 | 0 to 2 x 1010 MeVBq/m3 |
110/230AC 50/60Hz |
903 | Measures noble gases at a reactor plant | |
| 0 to 1 x 1011 Bq/m3 |
110/230AC 50/60Hz |
8102 | |||
| High-Level Beta-Gamm Portable Survey Monitors |
|||||
| 500mR/hr | 500R/hr | 110/230AC 50/60Hz |
AN/PDR43 | ||
| 500mR/hr | 500R/hr | AN/PDR45 | |||
| Portal Monitors: | |||||
| NMPM-P Series | |||||
| NMPM-1 Series | |||||
| CBRM-1 Series | |||||
| PPRM-1 Series |
| Model Number | Optional Low Range Sensitivity: | Top Of Range: | Power: | Model Numbers: | Comments: |
|---|---|---|---|---|---|
| T in H20 Series | 3.7 kBq/L | 110/230AC and 24VDC |
Liquid Scintillation Counting | ||
| Iodine Monitor | |||||
| RIM971 Series |