| Monitor For: | TA Model: | Type: | Portable: | Used For: |
|---|---|---|---|---|
| AREA: | FML-5A | GM | No | Detecting X-ray radiation in an area, alert to rise in radiation levels. Also sees Gamma. |
| FML-5B | GM | No | Detecting X-ray radiation in an area, alert to rise in radiation levels. Also sees Gamma. | |
| WA-2A Series | GM | Yes | Detecting X-ray radiation in an area, alert to rise in radiation levels. Also sees Gamma. | |
| FLOOR: | ABFM-7 | Gas Dual Flow | Yes | Check Floor for Radiation. Also Detects Alpha-Beta-Gamma, Beta-Gamma Only, and Alpha Only. |
| LEAKAGE DETECTOR: | P-8Neon | GM | Yes | Use wand to identify area of radiation leakage. Also Detects Alpha-Beta-Gamma. |
| RATEMETER/FIELD STRENGTH: | TBM-10 | GM | Yes | Reads down to background. Also detects Alpha-Beta-Gamma. |
| TBM-3R | GM | Yes | Detect field strength. Also sees Gamma. | |
| TBM-ICLR | GM | Yes | Low Range TBM-IC Meter. Also sees Gamma. | |
| TBM-XR | Scintillation | Yes | Used to detect exact amount of X-Ray leakage from Machine. | |
| TBM-EXR | Scintillation | Yes | Used to detect exact amount of X-Ray leakage from Machine. | |
| TBM-ICMark V | Ion Chamber | Yes | Rate plus Dose Digital Readout. Also Detects Alpha-Beta-Gamma. | |
| SMALL ANIMAL WHOLE BODY COUNTER: | LIVE-1 | Scintillation | No | Designed to quantify level of radiation present in a small animal placed inside the chamber. Also sees Gammas. |
| Probes TA Model: | Use With: | Type: | Energy Range: | Used For: |
|---|---|---|---|---|
| P-1212 | PUG-7, PRS-5, FS-5T, LAM-10 | GM | Also sees Alpha-Beta. | |
| P-15 | TBM-15,PUG-7, PRS-5, FS-5T, LAM-10 | GM | Also sees Alpha-Beta-Gamma. | |
| P-15-4 | PUG-7, PRS-5, FS-5T, LAM-10 | GM | Also sees Alpha-Beta-Gamma. | |
| P-15A | PUG-7, PRS-5, FS-5T, LAM-10 | GM | Also sees Alpha-Beta-Gamma. | |
| P-6A | PUG-7, PRS-5, FS-5T, LAM-10 , SML-2 | Scintillation | Also sees Alpha-Beta-Gamma. | |
| P6-LB | PUG-7, PRS-5, FS-5T, LAM-10 , TBM-6A | Scintillation | Also sees Alpha-Beta-Gamma. | |
| PGS-3I | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Gamma and Iodine. |
| PGS-3IBe | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Gamma and Iodine. |
| PGS-3LS | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation | Also sees Gamma. | |
| PGS-3T | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Beta-Gamma and Iodine. |
| PGS-3TBe | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Beta-Gamma. |
| PGS-22 | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Gamma. |
| PGS-32T | PUG-7, PRS-5, FS-5T, LAM-10 | Scintillation NaI(Tl) | Low-Med | Also sees Gamma and Iodine. |
| PPG-100 | Gas Proportional | Also sees Alpha-Beta-Gamma. | ||
| PPG-31 | HSM-10A | Gas Proportional or GM | Also sees Alpha-Beta-Gamma. | |
| PPG-41 | HSM-10A, PPG-27 | Gas Proportional or GM | Also sees Alpha-Beta-Gamma. Larger sensitivity area. |
|
|
|
|
|
|
|
|
|
|
|