FULL FEATURED ELECTRONIC
PERSONAL DOSIMETER
Model # PD-10i
FEATURES:
- ACCURATE
- RUGGED
- FULL FEATURED DOSIMETER
- DOSE
- DOSE RATE
- CHIRPER
- STAY TIME ALARMS
- SMALL SIZE
- LIGHTWEIGHT
- ADJUSTABLE ALARMS
- NO READER REQUIRED
|

Figure 1: PD-10i
|
Through patented innovations and advanced microelectronics,
Technical Associates offers a full-featured electronic dosimeter in
a stand-alone, pager-sized for personal use. The PD-10i
continues the heritage of accuracy and reliability found in
Technical Associates Dosimetry Products. Pushbuttons on the front
allow the user to adjust alarm set-points and chirp increments. In
addition, numerous dosimeter functions can be enabled or disabled
to suit your personal needs. This feature eliminates the need for
a computer/reader interface when versatility and low system cost are
a primary concern. The Liquid Crystal Display on the dosimeter steps
through Total Dose, Dose Rate, Stay-Time and Set-Point Confirmation
displays. The PD-10i is operational as
a stand alone Dosimeter or it can be used with other Technical Associates
Dosimetry Products.
SPECIFICATIONS:
- SIZE: 48 mm x 72 mm x 17 mm.
- WEIGHT: Less than 90 grams with battery.
- RUGGEDNESS: Exceeds drop test requirements
of ANSI N13.27 - 1981 (Tested for 40 drops from 1 meter onto concrete).
- DETECTOR: Energy compensated miniature
Geiger-Mueller tube.
- DOSE RANGE: 0µR to 999
R.
- DOSE RESOLUTION: < 2 µR.
- DOSE RATE RANGE: ±15%
or ±20% µR/h from Background to 500 R/h.
(Does not include counting statistics which are < ±20%
(1s) for rates above 10 mR/h).
- FOLD OVER: No foldover up to 10,000 R/h.
- ENERGY RESPONSE: Tissue equivalent to
within ±25% from 55 KeV to 6 MeV (-70% response at
40 KeV).
- ALARM SETPOINT RANGE: Alarms are set
with dosimeter pushbuttons or through the PDR-1 Reader.
- DOSE: 10 µR to 999 R.
- DOSE WARNING: 10 µR to 999
R.
- DOSE RATE: 40 µR/h to 999
R/h.
TATECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
$Revision: 1.1 $
FULL FEATURED ELECTRONIC
PERSONAL DOSIMETER
Model # PD-10i
SPECIFICATIONS (Continued):
- STAY TIME: 6 seconds to 109 hours.
- STAY TIME WARNING: 6 seconds to 109 hours.
- VISUAL ALARMS: Dose alarm flashes DOSE;
Dose rate alarm flashes RATE; Stay Time shows ``m''. Low battery
voltage indicated by battery icon with at least 24 hours of remaining
life.
- AUDIO ANNUNCIATOR:
Speaker sound level >75 dBA at 30 cm (continuous tone).
Dose/Warning Alarms: Continuous double/single beat until acknowledged.
Rate Alarm: Continuous beeping while above Rate alarm.
Stay Time/Warning Alarm: Continuous double/single beat until acknowledged.
- DISPLAY:
Liquid Crystal Display (LCD) with push-button controlled backlight.
Autoranging three digit floating point readout (µR, mR, or R units).
Low Battery Indicator
Gamma icon (g) flashes once per Geiger pulse (1.5 µR).
- CHIRP: One beep per pre-set dose increment.
Dose increment setting range: 2 µR to 50 mR.
- DOSE HISTORY:
>200 points (accessible with PDR-1 Reader).
Interval Range: 0 to 109 hours in 6 second increments.
- BUILT IN TEST: Continuous monitoring
of High Voltage Power Supply and GM Tube. Abnormal operation indicated
by LCD message and audio annunciator.
- ACCESS STATUS: PDR-1 toggled flag selects
normal data display or the word Out (logged out).
- TAMPER STATUS: PDR-1 readable flag indicates
unauthorized, temporary battery removal.
- SERIAL INTERFACE: Bidirectional serial
port (accessible via the battery well) for driving remote devices
including larger active displays, RS-485 or PLC communication ports,
radio transmitters, etc...
- POWER:
Compatible with any AA size battery with output voltages from 1.25 to 3.6 VDC.
Battery Life (normal use): Duracell Alkaline > 2250 hours in 10 mR/h field.
Battery Life (Idle Mode) Any chemistry Battery lasts for the shelf life of that battery.
- ENVIRONMENTAL:
Operating Temperature: -28°C to +60°C.
Humidity: Up to 95% R.H., non-condensing.
Vibration: Every dosimeter vibrated to > 6 g rms prior to shipping.
- CALIBRATION: Factory calibration valid
to first of 10 years or 300 R of accumulated exposure. Factory recalibration
is available.
- USER SET OPTIONS: Rate Display, Rate
Audio Alarm, Switch to Rate Display on Rate Alarm, Stay Time Display,
6 second Backlight Hold, Minimum Units in µR or mR, Default
Rate Reading, Truncation of Fractional mR Dose, Anti-Theft Alarm,
Dose History Buffer Organization, Dose initialization on power up
(zero or pre-powerdown value), Idle Mode Disable, Local/Remote Mode
Control.
- AVAILABLE ACCESSORIES: Audio Alarm ear
piece or headset, AA-4 Audio Alarm Amplifier (110 dBA output), and
custom front panel labels.
TATECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
$Revision: 1.1 $
2002-10-28