RAD Safety Water Monitor
Model # MEDA-SP
|
FEATURES:
- TWO SEPARATE DETECTORS
- SUBMERSIBLE GAMMA DETECTOR
- ENHANCED RESPONSE FOR RADIATION FROM 5 KeV TO 250 KeV (optional BGO)
- PANCAKE GEIGER OPERATION INTERNAL
- LIGHTWEIGHT - FITS IN YOUR BRIEFCASE
|

MEDA-SP
|
APPLICATION:
- Roadside Chemical Spill
- Industrial Accident
- Terrorist Water Poisoning
- Dumping of Medical/Industrial Waste
SITE LOCATION:
MEASURMENT CAPABILITIES:
- Gamma emitters, submersible sensor probes for reservoir, stream or sump.
- Alpha and beta emitters in water samples
- Quick determination of water contamination
- Easy detection of surface contamination-alpha, beta, gamma;
hands, boots, clothing and equipment
- Identify personnel needing decontamination
- Search out stored radioactive materials or dirty bombs using gamma probe
RAD Safety Water Monitor
Model # MEDA-SP
DESCRIPTION OF USE
- Arrive at location of accident or attack
- Throw gamma sensor into reservoir, stream or sump.
- Increasing count rate indicates contamination by gamma emitters.
2. Use PAN-AL (disposable planchet)
- Place sample of suspect water in evaporator (EVP) for one minute
- Place sample under built-in pancake detector on bottom of ratemeter
- Increased count rate indicates contamination with alpha or bet emitters
To Separate Alphas, Betas, and Gammas
- Built-in sliding beta filter is standard
- Alpha filter is optional
- If count rate exceeds 2 times background, water is not safe.
- Use built-in pancake GM detector on bottom of ratemeter to check people,
clothing and objects for surface contamination.
- If count rate exceeds 2 times background, the person should take off the contaminated clothing. If count rate continues to exceed 2 times the background, hose them down and measure again.
- Gamma probe count rate will increase as you approach a cache of radioactive materials. Knowing this you can search a car or check-out suspicious objects.
DESCRIPTION: The MEDA-SP RATEMETER features an internally mounted 2 inch pancake GM detector with window looking downward from bottom of case and an external crystal scintillation probe for detection of low energy gammas. A sliding shield protects pancake detector when not in use. This system is half the weight of other systems.
SPECIFICATIONS:
- Meter:
Rugged, recessed 2-1/2'' meter.
- Ranges:
4 linear for each detector: 0-500; 5,000; 50,000; 500,000 cpm for external and 0-0.15; 1.5; 15; 150 mR/hr. for internal detector. Other scales and overlays available: Sieverts, etc.
- Range Switch Positions:
Off; Battery Test; X1; X10; X100; X1,000.
- Detector Switch (Toggle):
Internal (pancake), External (scintillator) PGS-3SUB
- Time Constant Switch:
Fast, Slow (approx. 2 & 11 sec.)
- Detectors:
2'' O.D. Pancake Geiger for internal Alpha/beta, submersible, high sensitivity gamma scintillation probe 1"x1". Nal (Tl) crystal standard. 2"x2" crystal optional.
- Efficiency:
]
- OPTIONS:
- EVAP-SP: Sample evaporator with vehicle adaptor or battery.
- PAN-AL: Disposable aluminum planchets for sample evaporation.
- PAN-SP: Re-usable planchets.
- PGS-3LSUB: 2"x2" crystal probe
- STB-3: Shileded pancake tube detector for enhanced alpha beta sensitivity
- Calibration:
Single master Cal Pot for each detector, plus individual Cal Pot for each scale. Pots adjust from outside case.
- Power:
9V Transistor battery (Eveready E1220 or equivalent). Battery life - 100 hrs. norm. operation.
- Dimensions:
3'' (7.6cm) wide x 5-1/4'' (13.3cm) long x2-1/4'' (6cm) deep.
- Total Weight:
2.5 lbs. (including probe and battery)
- Shipping Weight:
4.4 lbs.